Glass Wire Wound Pt RTD Elements Class B (IEC-751), Alpha = 0.00385
G / GX / GN / KN Series
Glass wire wound platinum RTD elements are made by winding a platinum wire onto a glass core and then fusing the exterior with glass. They are suitable for low or very high temperatures and are tolerant of thermal shocks. They offer good vibration resistance (depending on mounting method) and can be immersed (with exception of GX) directly into liquid media.

The Glass wire wound platinum RTD “GN” Series has a platinum band wound into a solid glass core and homogeneously fused with the exterior glass.

The “GX” Series has one or two platinum bands wound onto a glass tube and protected from the environment by a layer of glaze.

NEWPORT’s RTD MI Cable!
Available in a wide selection of conductor configurations and sheath materials.


Dimensions in millimeters (1 mm = .03937")
G Series
1PT00G3545
1PT00G1050
 
1PT00G1730
*2PT00G3550
 
GX / GN Series
 
1PT00GX0518
1PT00GN1020
1PT00GX1013
1PT00GN1327
1PT00GX1510
1PT00GN1545
*2PT00GX1528
KN Series
 
1PT00KN1515CLA
1PT00KN3026CLA
 
1PT00KN2515CLA
*2PT00KN3045CLA
 
1PT00KN3045CLA
*2PT00KN3026CLA
 

To Order (Specify Model Number)
Model No.
Nominal Resistance Ohms
Temp. Range
°C (°F)
Self Heating error in °C/mW Flowing Air V=1m/sec
Response Time in Secs.
Price
Water
V=0.4 m/s
Moving Air V=1 m/s
50%
90%
50%
90%
G Series
1PT100G3545
1 x 100
0 to 600
(32 to 1110)
0.04
0.7
2.0
12.0
38.0
$68
1PT100G1730
1 x 100
0 to 600
(32 to 1110)
0.11
0.7
2.0
8.0
28.0
$54
1PT100G1050
1 x 100
0 to 600
(32 to 1110)
0.12
0.8
3.0
11.0
34.0
$109
*2PT100G3550
2 x 100
0 to 600
(32 to 1110)
0.02
0.8
2.5
13.0
40.0
$162
GX Series
1PT100GX0518
1 x 100
-200 to 400
(-365 to 750)
0.36
0.2
0.8
8.0
30.0
$45
1PT100GX1013
1 x 100
-220 to 400
(-365 to 750)
0.39
0.2
0.5
4.0
12.0
$45
1PT100GX1510
1 x 100
-220 to 400
(-365 to 750)
0.36
0.2
0.4
2.0
7.0
$51
*2PT100GX1528
2 x 100
-220 to 400
(-365 to 750)
0.20
0.3
1.0
12.0
45.0
$84
GN Series
1PT100GN1020
1 x 100
-220 to 400
(-365 to 750)
0.26
0.14
0.35
7.0
21.0
$25
1PT100GN1327
1 x 100
-220 to 400
(-365 to 750)
0.11
0.40
1.30
13.0
25.0
$25
1PT100GN1545
1 x 100
-220 to 400
(-365 to 750)
0.09
0.80
2.40
16.0
40.0
$24
KN Series
1PT100KN1515CLA
1 x 100
-200 to 600
(-330 to 1110)
0.08
0.2
0.6
5
18
$17
1PT100KN2515CLA
1 x 100
-200 to 600
(-330 to 1110)
0.08
0.2
0.6
5
18
$13
1PT100KN3045CLA
1 x 100
-200 to 600
(-330 to 1110)
0.21
0.2
0.6
2.5
9
$21
*2PT100GX1528
1 x 100
-200 to 600
(-330 to 1110)
0.06
0.3
0.7
15
50
$39
1PT100GX1510
2 x 100
-200 to 600
(-330 to 1110)
0.08
0.2
0.6
5
18
$56
*2PT100GX1528
2 x 100
-200 to 600
(-330 to 1110)
0.06
0.3
0.7
15
50
$39
* Dual Element
Leads are 10 mm long.


Ceramic Wire Wound Platinum RTD Elements, Class A (IEC-751), Alpha = 0.00385
The “KN” series RTD‘s are suitable for applications requiring extremely high temperature stability and high temperature shock resistance. Deviation from the IEC751 characteristic curve is minimal over the entire temperature range. The small diameter tolerances of the sensor body allow easy installation in protective tubes. Applications are found in chemical and power generation plants and analytical equipment.

All RTD elements come standard with 10 or 15 mm leads. Welded insulated extension leads available. Pricing is dependent on lead style, See page with
"RTD Elements with Lead Wires Attatched".

Copyright 2003, NEWPORT Electronics, Inc. All rights reserved.
SearchSite MapManualsPricelistQuotesPurchaseProductsNewport Homee-mail NEWPORT HOME Newport Home Purchase Quotes Products Newport Home Pricelist Manuals Site Map Search e-mail