2-WIRE
TRANSMITTER FOR LOAD CELLS AND PRESSURE TRANSDUCERS
Converts mV/V to 4 to 20 mA output
This
is a 2-wire, 4-20 mA Current Transmitter that accepts signals from
350, 500, 1K, 2.5K and 5K ohm bridges and provides the amplification
and common-mode rejection necessary to control the current drawn from
a 8 to 40 Vdc source to produce the 4-20 mA output signal. The transmitter
is designed for 0.5 to 4.0 mV/V bridge sensitivities. The transmitter
does not provide isolation between its input and the 4-20 mA output.
It has two internal reference voltages for powering the bridge. The
1.24 volt reference is used with 1K ohm and lower resistance bridges.
The 2.5 volt reference is used with 2.5K and 5K ohm bridges.
SPECIFICATIONS Input Span: User Selectable, 0.5 mV/V to 4 mV/V Input Impedance: > or = to 10 Mohm Output Span: 4 to 20 mA Min. Output Current: 3.75 mA typical Max. Output Current: 22 mA typical Supply Voltage Range: 8 to 40 Vdc Transducer Excitation: Selectable, 1.24 Vdc or 2.5 Vdc Zero & Span Adjustability: 10% of any selected range Accuracy: (includes linearity, hysteresis, stability) 0.5% of any adjusted span Repeatability: 0.05% of span Response Time: 200 ms typical Stability: Zero: within 0.02% of span/°C or 5 µA, whichever is greater. Span: within 0.01% of span/°C Max. Leadwire Resistance Effect: Less than 0.25 µV per ohm Maximum Change-In-Supply Voltage Effect: 0.05% of span over supply range Output Ripple: Less than 0.05% of span, rms Operating Temperature Range: -45 to 85°C (-49 to 185°F) To Order (Specify Model No.) Prices Shown in U.S. Dollars
Ordering Example:
PXTX-507-EPH1-ATEX is a PXTX-507 strain transmitter in a NEMA-7 enclosure, $195 + 108 =$303. |
||||||||||||||||||||||||||||||||||||||||||||||
|
Copyright 2003,