FACTORY
& NIST CALIBRATIONS for SENSORS, WIRE & INSTRUMENTS
CALL
OR E-MAIL FOR PRICING |

ICE
POINT |
NEWPORT's ICE POINT is a highly accurate 0ºC
Thermoelectric "Refrigerator" Used in the Calibration of
Temperature Instruments. Model TRCIII.
With calibration instrumentation conforming to MIL-STD-45662A,
NEWPORT can calibrate individual products (both new and
existing) or complete systems, with NIST traceability if
required. Scheduled, periodic calibration of equipment is
easily arranged as well.
Probes and instruments that may be calibrated at customer-specified
temperatures:
- Thermocouple and RTD probes (thermistor must be calibrated
as a system with a meter and wire).
- Thermocouple wire.
- Probe/meter systems.
- Meters/instrumentation.
|
Wire calibration
requires cutting approximately 3' from the spool being tested,
forming a bead and performing the calibrations. The tested wire
will be sent along with the spool and certification.
HOT
POINT
 |
NEWPORT's
HOT POINT Thermocouple and RTD Calibrator Calibrates
All Temperature Sensors to Within ±1.5ºF.
|
CALIBRATION SERVICES
AVAILABLE FROM NEWPORT
INSTRUMENTS
& PROBES
Upon request, NEWPORT will guarantee products Probes Certificate
of ANSI are manufactured in accordance with all applicable Conformance/
instructions and specifications. NEWPORT certifies Compliance
that all thermocouple materials conform to ANSI standard MC96.1.
RTD materials conform to DIN 43 760.
Model No.CAL-1
Certificate of ANSI Conformance/ Compliance
NIST TRACEABLE INSTRUMENTATION
Upon request, NEWPORT will certify that Instrumentation has been
calibrated and tested to meet or exceed published specifications.
Calibration and testing are performed using instrumentation and
standards traceable to the U.S. National Institute of Standards
and Technology (NIST).
Model No. CAL-2
NIST Traceability Certification
NIST TRACEABILITY OF INSTRUMENTATION
Same as CAL-2, with the addition of the NIST test numbers for
reference. 5 fixed points of data.
Model No. CAL-3
Certificate with NIST Test Number $75
NIST TRACEABLE CALIBRATION
OF PROBES
NEWPORT certifies that the item has been calibrated and the calibration
is certified as traceable to NIST. NIST test numbers are documented
on the certificate for traceability. Pricing: $75 setup
charge plus $25 per temperature calibration point for thermocouples
or $35 per temperature calibration point for RTDs. For wire, setup
charge is $90.
Model No. CAL-4
Certificate NIST Traceable Calibration at Customer Specified Temperature
Points* From $100
FACTORY CALIBRATION OF PROBES
Available for Types J, K, T, E and N mineral insulated thermocouples:
quick disconnect, transition junction, utility handle, and low-noise
styles. Each probe certified at four temperature standards. Calibration
card included "pre-stocked" with each probe.
Model No. CAL-5
Factory Calibration Certificate $15, probe calibrated at 4 fixed
temperature points
|
Temperature
Range
|
Equipment
|
Accuracy
|
|
-25 to 100ºC
|
Fluid
bath
|
Minimum
probe length 3". Accurate to 0.2ºC. |
|
100
to 400ºC
|
Aerated
sand bath
|
Minimum
probe length 7". Accurate to ±0.4ºC. |
|
400
to 1000ºC
|
Hot
air oven
|
Minimum
probe length is 18". Accurate to ±0.25% of the specified
temperature. |
|
|